Select the span of the VMM floor (pre-stressed concrete floor) and the DRAHEIM TRÄGER. Reasonable beam heights are usually between 1/15 and 1/20 of the beam span. The VMM ceilings always meet F90. In the event of fire protection requirements, the exposed support part must be protected with an appropriate coating system or fire protection panels.
A suitable combination (utilization ≤ 100%) of ceiling tile and DRAHEIM TRÄGER is done by clicking on the corresponding table line. With the VMM ceilings, the V-utilization should not exceed 70%.
The top flange of the DRAHEIM TRÄGER lies completely inside the ceiling. Three generous openings are available below the ceiling.
Different configurations, e.g. With different ceiling spans, a version with element ceilings (filigree), taking into account individual loads or significantly stronger beams are also possible on request.